Diagnostic value of electrophysiological tests in patients with sciatica

Research output: Contribution to journalJournal articleResearchpeer-review

Objectives - To assess the diagnostic value of electrophysiological tests in patients with sciatica. Materials and methods - The diagnostic value of electrophysiological tests were evaluated in 25 patients with mono- radicular sciatica. The electrophysiological study included dermatomal somatosensory evoked potentials, electromyography, F-wave latencies, H- reflexes and motor and sensory nerve conduction determinations. The results of the electrophysiological examinations were evaluated blindly, and the test results were analysed separately by a receiver operating characteristic (ROC) analysis. Furthermore, the 5 modalities were evaluated jointly and analysed by a decision-analytic regret function. Results - A high predictive value was found for the H-reflex examination, but low for the other modalities. When the 5 modalities were evaluated jointly, a non-significant decrease in expected regret from the pre-test situation of 0.96 to a value of 0.93 in post-test situation was revealed. Conclusion - Electrophysiological testing is not sufficient as stand-alone examination in patients with sciatica.

Original languageEnglish
Book seriesActa Neurologica Scandinavica
Volume101
Issue number4
Pages (from-to)249-254
Number of pages6
ISSN0001-6314
Publication statusPublished - 28 Mar 2000

    Research areas

  • Diagnostic test, Electrophysiological test, Evoked potential, Intervertebral disc displacement

ID: 201453573