Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke. / Busk, Henriette; Nielsen, Marianne; Pedersen, Julie Rønne; Kristensen, Malene Glavind ; Kjær, Troels Wesenberg; Skou, Søren Thorgaard; Wienecke, Troels.

In: Neuroscience Insights, Vol. 17, 2022.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Busk, H, Nielsen, M, Pedersen, JR, Kristensen, MG, Kjær, TW, Skou, ST & Wienecke, T 2022, 'Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke', Neuroscience Insights, vol. 17. https://doi.org/10.1177/26331055221145002

APA

Busk, H., Nielsen, M., Pedersen, J. R., Kristensen, M. G., Kjær, T. W., Skou, S. T., & Wienecke, T. (2022). Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke. Neuroscience Insights, 17. https://doi.org/10.1177/26331055221145002

Vancouver

Busk H, Nielsen M, Pedersen JR, Kristensen MG, Kjær TW, Skou ST et al. Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke. Neuroscience Insights. 2022;17. https://doi.org/10.1177/26331055221145002

Author

Busk, Henriette ; Nielsen, Marianne ; Pedersen, Julie Rønne ; Kristensen, Malene Glavind ; Kjær, Troels Wesenberg ; Skou, Søren Thorgaard ; Wienecke, Troels. / Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke. In: Neuroscience Insights. 2022 ; Vol. 17.

Bibtex

@article{549d54e0d100477fb9f4378f4f1edf64,
title = "Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke",
abstract = "Background:Transcranial magnetic stimulation (TMS) is often used to examine neurophysiology. We aimed to investigate the inter-rater reliability and agreement of single pulse TMS in hospitalised acute ischemic stroke patients.Methods:Thirty-one patients with first-time acute ischemic stroke (median age 72 (IQR 64-75), 35% females) underwent TMS motor threshold (MT) assessment in 4 muscles bilaterally, conducted by 1 of 2 physiotherapists. Test-retest reliability was evaluated using a two-way random effects model (2,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC) were used to evaluate agreement.Results:Reliability, SEM, and SDC of TMS was found to be moderate in right opponens pollicis (0.78 [CI 95% 0.55-0.89], SEM: 4.51, SDC: 12.51), good in right vastus medialis and tibial anterior (0.88 [CI 95% 0.72-0.96], SEM: 2.89, SDC: 8.01 and 0.88 [CI 95% 0.76-0.94], SEM: 2.88, SDC: 7.98 respectively), and excellent in right and left biceps brachii (0.98 [CI 95% 0.96-0.99], SEM: 1.79 SDC: 4.96, and 0.94 [CI 95% 0.89-0.97], SEM: 2.17 SDC: 6.01), opponens pollicis (0.92 [CI 95% 0.83-0.96], SEM: 2.68 SDC: 8.26, vastus medialis (0.92 [CI 95% 0.84-0.96], SEM: 2.87 SDC: 7.95), and tibial anterior (0.93 [CI 95% 0.86-0.96], SEM: 2.51 SDC: 6.95).Conclusion:The TMS demonstrated moderate to excellent inter-rater reliability confirming the ability of these measures to reliably discriminate between individuals in the current study sample. Improvements of less than 4.96 to 12.51 could be a result of measurement error and may therefore not be considered a true change.",
author = "Henriette Busk and Marianne Nielsen and Pedersen, {Julie R{\o}nne} and Kristensen, {Malene Glavind} and Kj{\ae}r, {Troels Wesenberg} and Skou, {S{\o}ren Thorgaard} and Troels Wienecke",
year = "2022",
doi = "10.1177/26331055221145002",
language = "English",
volume = "17",
journal = "Neuroscience Insights",
issn = "2633-1055",
publisher = "SAGE Publications",

}

RIS

TY - JOUR

T1 - Test-Retest Reliability and Agreement of Single Pulse Transcranial Magnetic Stimulation (TMS) for Measuring Activity in Motor Cortex in Patients With Acute Ischemic Stroke

AU - Busk, Henriette

AU - Nielsen, Marianne

AU - Pedersen, Julie Rønne

AU - Kristensen, Malene Glavind

AU - Kjær, Troels Wesenberg

AU - Skou, Søren Thorgaard

AU - Wienecke, Troels

PY - 2022

Y1 - 2022

N2 - Background:Transcranial magnetic stimulation (TMS) is often used to examine neurophysiology. We aimed to investigate the inter-rater reliability and agreement of single pulse TMS in hospitalised acute ischemic stroke patients.Methods:Thirty-one patients with first-time acute ischemic stroke (median age 72 (IQR 64-75), 35% females) underwent TMS motor threshold (MT) assessment in 4 muscles bilaterally, conducted by 1 of 2 physiotherapists. Test-retest reliability was evaluated using a two-way random effects model (2,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC) were used to evaluate agreement.Results:Reliability, SEM, and SDC of TMS was found to be moderate in right opponens pollicis (0.78 [CI 95% 0.55-0.89], SEM: 4.51, SDC: 12.51), good in right vastus medialis and tibial anterior (0.88 [CI 95% 0.72-0.96], SEM: 2.89, SDC: 8.01 and 0.88 [CI 95% 0.76-0.94], SEM: 2.88, SDC: 7.98 respectively), and excellent in right and left biceps brachii (0.98 [CI 95% 0.96-0.99], SEM: 1.79 SDC: 4.96, and 0.94 [CI 95% 0.89-0.97], SEM: 2.17 SDC: 6.01), opponens pollicis (0.92 [CI 95% 0.83-0.96], SEM: 2.68 SDC: 8.26, vastus medialis (0.92 [CI 95% 0.84-0.96], SEM: 2.87 SDC: 7.95), and tibial anterior (0.93 [CI 95% 0.86-0.96], SEM: 2.51 SDC: 6.95).Conclusion:The TMS demonstrated moderate to excellent inter-rater reliability confirming the ability of these measures to reliably discriminate between individuals in the current study sample. Improvements of less than 4.96 to 12.51 could be a result of measurement error and may therefore not be considered a true change.

AB - Background:Transcranial magnetic stimulation (TMS) is often used to examine neurophysiology. We aimed to investigate the inter-rater reliability and agreement of single pulse TMS in hospitalised acute ischemic stroke patients.Methods:Thirty-one patients with first-time acute ischemic stroke (median age 72 (IQR 64-75), 35% females) underwent TMS motor threshold (MT) assessment in 4 muscles bilaterally, conducted by 1 of 2 physiotherapists. Test-retest reliability was evaluated using a two-way random effects model (2,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC) were used to evaluate agreement.Results:Reliability, SEM, and SDC of TMS was found to be moderate in right opponens pollicis (0.78 [CI 95% 0.55-0.89], SEM: 4.51, SDC: 12.51), good in right vastus medialis and tibial anterior (0.88 [CI 95% 0.72-0.96], SEM: 2.89, SDC: 8.01 and 0.88 [CI 95% 0.76-0.94], SEM: 2.88, SDC: 7.98 respectively), and excellent in right and left biceps brachii (0.98 [CI 95% 0.96-0.99], SEM: 1.79 SDC: 4.96, and 0.94 [CI 95% 0.89-0.97], SEM: 2.17 SDC: 6.01), opponens pollicis (0.92 [CI 95% 0.83-0.96], SEM: 2.68 SDC: 8.26, vastus medialis (0.92 [CI 95% 0.84-0.96], SEM: 2.87 SDC: 7.95), and tibial anterior (0.93 [CI 95% 0.86-0.96], SEM: 2.51 SDC: 6.95).Conclusion:The TMS demonstrated moderate to excellent inter-rater reliability confirming the ability of these measures to reliably discriminate between individuals in the current study sample. Improvements of less than 4.96 to 12.51 could be a result of measurement error and may therefore not be considered a true change.

U2 - 10.1177/26331055221145002

DO - 10.1177/26331055221145002

M3 - Journal article

VL - 17

JO - Neuroscience Insights

JF - Neuroscience Insights

SN - 2633-1055

ER -

ID: 357425438