Comparing the air quality performance in unoccupied storage buildings between mechanical ventilation and semi-passive climate control
Publikation: Bidrag til bog/antologi/rapport › Konferencebidrag i proceedings › Forskning › fagfællebedømt
Standard
Comparing the air quality performance in unoccupied storage buildings between mechanical ventilation and semi-passive climate control. / Smedemark, Signe Hjerrild; Ryhl-Svendsen, Morten; Toftum, Jørn.
International Council of Museums - Committee for Conservation, Beijing, China, 17/05/2021. 2021.Publikation: Bidrag til bog/antologi/rapport › Konferencebidrag i proceedings › Forskning › fagfællebedømt
Harvard
APA
Vancouver
Author
Bibtex
}
RIS
TY - GEN
T1 - Comparing the air quality performance in unoccupied storage buildings between mechanical ventilation and semi-passive climate control
AU - Smedemark, Signe Hjerrild
AU - Ryhl-Svendsen, Morten
AU - Toftum, Jørn
PY - 2021/5/18
Y1 - 2021/5/18
N2 - Air pollution can damage heritage collections.This study examines the air quality performancein one store with mechanical ventilation andin another with semi-passive climate control.Air pollution was measured with passive diffusionsamplers during summer and winter. Theatmospheric corrosivity was determined gravimetricallyusing copper, zinc and lead coupons,and by a real-time electrical resistance monitorover one year. The concentration of outdoorgeneratedair pollution was low within bothstores. The emission of formic acid and aceticacid from internal sources led to higher indoorconcentrations. The total acid concentrationwas 15 μg m-3 in the store with mechanical ventilationand 97 μg m-3 in the store with semipassiveclimate control. The indoor atmosphericcorrosivity was determined as very low by bothmethods. The study demonstrated that storesusing mechanical ventilation with air filtrationand semi-passive climate control provide acceptableair quality for the preservation of heritagecollections.
AB - Air pollution can damage heritage collections.This study examines the air quality performancein one store with mechanical ventilation andin another with semi-passive climate control.Air pollution was measured with passive diffusionsamplers during summer and winter. Theatmospheric corrosivity was determined gravimetricallyusing copper, zinc and lead coupons,and by a real-time electrical resistance monitorover one year. The concentration of outdoorgeneratedair pollution was low within bothstores. The emission of formic acid and aceticacid from internal sources led to higher indoorconcentrations. The total acid concentrationwas 15 μg m-3 in the store with mechanical ventilationand 97 μg m-3 in the store with semipassiveclimate control. The indoor atmosphericcorrosivity was determined as very low by bothmethods. The study demonstrated that storesusing mechanical ventilation with air filtrationand semi-passive climate control provide acceptableair quality for the preservation of heritagecollections.