Automatic Detection of B-Lines in In Vivo Lung Ultrasound

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

Automatic Detection of B-Lines in In Vivo Lung Ultrasound. / Moshavegh, Ramin; Hansen, Kristoffer Lindskov; Moller-Sorensen, Hasse; Nielsen, Michael Bachmann; Jensen, Jorgen Arendt.

In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 66, No. 2, 02.2019, p. 309-317.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

Moshavegh, R, Hansen, KL, Moller-Sorensen, H, Nielsen, MB & Jensen, JA 2019, 'Automatic Detection of B-Lines in In Vivo Lung Ultrasound', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 66, no. 2, pp. 309-317. https://doi.org/10.1109/TUFFC.2018.2885955

APA

Moshavegh, R., Hansen, K. L., Moller-Sorensen, H., Nielsen, M. B., & Jensen, J. A. (2019). Automatic Detection of B-Lines in In Vivo Lung Ultrasound. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 66(2), 309-317. https://doi.org/10.1109/TUFFC.2018.2885955

Vancouver

Moshavegh R, Hansen KL, Moller-Sorensen H, Nielsen MB, Jensen JA. Automatic Detection of B-Lines in In Vivo Lung Ultrasound. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2019 Feb;66(2):309-317. https://doi.org/10.1109/TUFFC.2018.2885955

Author

Moshavegh, Ramin ; Hansen, Kristoffer Lindskov ; Moller-Sorensen, Hasse ; Nielsen, Michael Bachmann ; Jensen, Jorgen Arendt. / Automatic Detection of B-Lines in In Vivo Lung Ultrasound. In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2019 ; Vol. 66, No. 2. pp. 309-317.

Bibtex

@article{5eac155766344e10ba047f8df4391fff,
title = "Automatic Detection of B-Lines in In Vivo Lung Ultrasound",
abstract = "This paper proposes an automatic method for accurate detection and visualization of B-lines in ultrasound lung scans, which provides a quantitative measure for the number of B-lines present. All the scans used in this study were acquired using a BK3000 ultrasound scanner (BK Ultrasound, Herlev, Denmark) driving a 5.5-MHz linear transducer (BK Ultrasound). Four healthy subjects and four patients, after major surgery with pulmonary edema, were scanned at four locations on each lung for B-line examination. Eight sequences of 50 frames were acquired for each subject yielding 64 sequences in total. The proposed algorithm was applied to all 3200 in-vivo lung ultrasound images. The results showed that the average number of B-lines was 0.28±0.06 (Mean±Std) in scans belonging to the patients compared to 0.03 ± 0.06 (Mean ± Std) in the healthy subjects. Also, the Mann-Whitney test showed a significant difference between the two groups with the p -value of 0.015, and indicating that the proposed algorithm was able to differentiate between the healthy volunteers and the patients. In conclusion, the method can be used to automatically and to quantitatively characterize the distribution of B-lines for diagnosing pulmonary edema.",
author = "Ramin Moshavegh and Hansen, {Kristoffer Lindskov} and Hasse Moller-Sorensen and Nielsen, {Michael Bachmann} and Jensen, {Jorgen Arendt}",
year = "2019",
month = feb,
doi = "10.1109/TUFFC.2018.2885955",
language = "English",
volume = "66",
pages = "309--317",
journal = "I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control",
issn = "0885-3010",
publisher = "Institute of Electrical and Electronics Engineers",
number = "2",

}

RIS

TY - JOUR

T1 - Automatic Detection of B-Lines in In Vivo Lung Ultrasound

AU - Moshavegh, Ramin

AU - Hansen, Kristoffer Lindskov

AU - Moller-Sorensen, Hasse

AU - Nielsen, Michael Bachmann

AU - Jensen, Jorgen Arendt

PY - 2019/2

Y1 - 2019/2

N2 - This paper proposes an automatic method for accurate detection and visualization of B-lines in ultrasound lung scans, which provides a quantitative measure for the number of B-lines present. All the scans used in this study were acquired using a BK3000 ultrasound scanner (BK Ultrasound, Herlev, Denmark) driving a 5.5-MHz linear transducer (BK Ultrasound). Four healthy subjects and four patients, after major surgery with pulmonary edema, were scanned at four locations on each lung for B-line examination. Eight sequences of 50 frames were acquired for each subject yielding 64 sequences in total. The proposed algorithm was applied to all 3200 in-vivo lung ultrasound images. The results showed that the average number of B-lines was 0.28±0.06 (Mean±Std) in scans belonging to the patients compared to 0.03 ± 0.06 (Mean ± Std) in the healthy subjects. Also, the Mann-Whitney test showed a significant difference between the two groups with the p -value of 0.015, and indicating that the proposed algorithm was able to differentiate between the healthy volunteers and the patients. In conclusion, the method can be used to automatically and to quantitatively characterize the distribution of B-lines for diagnosing pulmonary edema.

AB - This paper proposes an automatic method for accurate detection and visualization of B-lines in ultrasound lung scans, which provides a quantitative measure for the number of B-lines present. All the scans used in this study were acquired using a BK3000 ultrasound scanner (BK Ultrasound, Herlev, Denmark) driving a 5.5-MHz linear transducer (BK Ultrasound). Four healthy subjects and four patients, after major surgery with pulmonary edema, were scanned at four locations on each lung for B-line examination. Eight sequences of 50 frames were acquired for each subject yielding 64 sequences in total. The proposed algorithm was applied to all 3200 in-vivo lung ultrasound images. The results showed that the average number of B-lines was 0.28±0.06 (Mean±Std) in scans belonging to the patients compared to 0.03 ± 0.06 (Mean ± Std) in the healthy subjects. Also, the Mann-Whitney test showed a significant difference between the two groups with the p -value of 0.015, and indicating that the proposed algorithm was able to differentiate between the healthy volunteers and the patients. In conclusion, the method can be used to automatically and to quantitatively characterize the distribution of B-lines for diagnosing pulmonary edema.

U2 - 10.1109/TUFFC.2018.2885955

DO - 10.1109/TUFFC.2018.2885955

M3 - Journal article

C2 - 30530325

VL - 66

SP - 309

EP - 317

JO - I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control

JF - I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control

SN - 0885-3010

IS - 2

ER -