A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material

Research output: Contribution to journalJournal articleResearchpeer-review

Standard

A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material. / van Dijken, Jan W V; Pallesen, Ulla.

In: Journal of Dentistry, Vol. 40, No. 12, 2012, p. 1060-7.

Research output: Contribution to journalJournal articleResearchpeer-review

Harvard

van Dijken, JWV & Pallesen, U 2012, 'A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material', Journal of Dentistry, vol. 40, no. 12, pp. 1060-7. https://doi.org/10.1016/j.jdent.2012.08.017

APA

van Dijken, J. W. V., & Pallesen, U. (2012). A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material. Journal of Dentistry, 40(12), 1060-7. https://doi.org/10.1016/j.jdent.2012.08.017

Vancouver

van Dijken JWV, Pallesen U. A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material. Journal of Dentistry. 2012;40(12):1060-7. https://doi.org/10.1016/j.jdent.2012.08.017

Author

van Dijken, Jan W V ; Pallesen, Ulla. / A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material. In: Journal of Dentistry. 2012 ; Vol. 40, No. 12. pp. 1060-7.

Bibtex

@article{a492e0fdb8fb4ae7bf6e9a19c765c2ef,
title = "A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material",
abstract = "Objective: The aim of this study was to evaluate the clinical retention of a one-step self-etching adhesive system (Xeno III) in Class V non-carious cervical lesions and the effect of restorative material and curing techniques on longevity of the restorations. Material and methods: A total of 139 Class V restorations were placed with the self-etching primer Xeno III and a resin composite (Tetric Ceram) or a poly-acid modified resin composite (Dyract AP) in non-carious cervical lesions without intentional enamel involvement. The materials were cured with a conventional continuous light, a soft-start or a pulse-delay curing mode. The restorations were evaluated at baseline, 6, 12, 18 and 24 months and then yearly during a 7 years follow-up with modified USPHS criteria. Dentin bonding efficiency was determined by the percentage of lost restorations. Results: During the 7 years, 135 restorations could be evaluated. No post-operative sensitivity was reported by the participants. Overall relative cumulative loss rate frequencies for the adhesive system at 6, 18 and 7 years, independent of curing technique and restorative material, were 0.8%, 6.9% and 23.0%, respectively. The self-etching adhesive fulfilled at 18 months the full acceptance ADA criteria. Tetric Ceram showed at 7 years a 20.9% loss of retention and Dyract AP a 25.0% loss rate (Log rank p=0.48). The loss rates for the 3 curing techniques: continuous, soft start and pulse delay were 17%, 27.9% and 24.4%, respectively (Log rank p=0.52)..No secondary caries was observed. Significance: The single-step self-etching adhesive showed acceptable clinical long-time retention rates to dentin surfaces independent of restorative material and curing technique used. ",
keywords = "Faculty of Health and Medical Sciences, adhesion, clinical, curing techniques, dental material, resin composite, restoration, self-etch",
author = "{van Dijken}, {Jan W V} and Ulla Pallesen",
note = "Copyright {\textcopyright} 2012 Elsevier Ltd. All rights reserved.",
year = "2012",
doi = "10.1016/j.jdent.2012.08.017",
language = "English",
volume = "40",
pages = "1060--7",
journal = "Journal of Dentistry",
issn = "0300-5712",
publisher = "Elsevier",
number = "12",

}

RIS

TY - JOUR

T1 - A 7-year randomized prospective study of a one-step self-etching adhesive in non-carious cervical lesions. The effect of curing modes and restorative material

AU - van Dijken, Jan W V

AU - Pallesen, Ulla

N1 - Copyright © 2012 Elsevier Ltd. All rights reserved.

PY - 2012

Y1 - 2012

N2 - Objective: The aim of this study was to evaluate the clinical retention of a one-step self-etching adhesive system (Xeno III) in Class V non-carious cervical lesions and the effect of restorative material and curing techniques on longevity of the restorations. Material and methods: A total of 139 Class V restorations were placed with the self-etching primer Xeno III and a resin composite (Tetric Ceram) or a poly-acid modified resin composite (Dyract AP) in non-carious cervical lesions without intentional enamel involvement. The materials were cured with a conventional continuous light, a soft-start or a pulse-delay curing mode. The restorations were evaluated at baseline, 6, 12, 18 and 24 months and then yearly during a 7 years follow-up with modified USPHS criteria. Dentin bonding efficiency was determined by the percentage of lost restorations. Results: During the 7 years, 135 restorations could be evaluated. No post-operative sensitivity was reported by the participants. Overall relative cumulative loss rate frequencies for the adhesive system at 6, 18 and 7 years, independent of curing technique and restorative material, were 0.8%, 6.9% and 23.0%, respectively. The self-etching adhesive fulfilled at 18 months the full acceptance ADA criteria. Tetric Ceram showed at 7 years a 20.9% loss of retention and Dyract AP a 25.0% loss rate (Log rank p=0.48). The loss rates for the 3 curing techniques: continuous, soft start and pulse delay were 17%, 27.9% and 24.4%, respectively (Log rank p=0.52)..No secondary caries was observed. Significance: The single-step self-etching adhesive showed acceptable clinical long-time retention rates to dentin surfaces independent of restorative material and curing technique used.

AB - Objective: The aim of this study was to evaluate the clinical retention of a one-step self-etching adhesive system (Xeno III) in Class V non-carious cervical lesions and the effect of restorative material and curing techniques on longevity of the restorations. Material and methods: A total of 139 Class V restorations were placed with the self-etching primer Xeno III and a resin composite (Tetric Ceram) or a poly-acid modified resin composite (Dyract AP) in non-carious cervical lesions without intentional enamel involvement. The materials were cured with a conventional continuous light, a soft-start or a pulse-delay curing mode. The restorations were evaluated at baseline, 6, 12, 18 and 24 months and then yearly during a 7 years follow-up with modified USPHS criteria. Dentin bonding efficiency was determined by the percentage of lost restorations. Results: During the 7 years, 135 restorations could be evaluated. No post-operative sensitivity was reported by the participants. Overall relative cumulative loss rate frequencies for the adhesive system at 6, 18 and 7 years, independent of curing technique and restorative material, were 0.8%, 6.9% and 23.0%, respectively. The self-etching adhesive fulfilled at 18 months the full acceptance ADA criteria. Tetric Ceram showed at 7 years a 20.9% loss of retention and Dyract AP a 25.0% loss rate (Log rank p=0.48). The loss rates for the 3 curing techniques: continuous, soft start and pulse delay were 17%, 27.9% and 24.4%, respectively (Log rank p=0.52)..No secondary caries was observed. Significance: The single-step self-etching adhesive showed acceptable clinical long-time retention rates to dentin surfaces independent of restorative material and curing technique used.

KW - Faculty of Health and Medical Sciences

KW - adhesion, clinical, curing techniques, dental material, resin composite, restoration, self-etch

U2 - 10.1016/j.jdent.2012.08.017

DO - 10.1016/j.jdent.2012.08.017

M3 - Journal article

C2 - 22955004

VL - 40

SP - 1060

EP - 1067

JO - Journal of Dentistry

JF - Journal of Dentistry

SN - 0300-5712

IS - 12

ER -

ID: 40387514