Postoperative volume balance: does stroke volume increase in Trendelenburg's position?

Research output: Contribution to journalJournal articleResearchpeer-review

In healthy humans, stroke volume (SV) and cardiac output (CO) do not increase with expansion of the central blood volume by head-down tilt or administration of fluid. Here, we exposed 85 patients to Trendelenburg's position about one hour after surgery while cardiovascular variables were determined non-invasively by Modelflow. In Trendelenburg's position, SV (83 ± 19 versus 89 ± 20 ml) and CO (6·2 ± 1·8 versus 6·8 ± 1·8 l/min; both P<0·05) increased, while heart rate (75 ± 15 versus 76 ± 14 b min(-1) ) and mean arterial pressure were unaffected (84 ± 15 versus 84 ± 16 mmHg). For the 33 patients (39%) with a > 10% increase in SV (from 78 ± 16 to 90 ± 17 ml) corresponding to an increase in CO from 5·9 ± 1·5 to 6·9 ± 1·6 l min(-1) (P<0·05) when tilted head-down, administration of 250 ml Ringer's lactate solution increased SV (to 88 ± 18 ml) and CO (to 6·8 ± 1·7 l min(-1) ). In conclusion, determination of SV and/or CO in Trendelenburg's position can be used to evaluate whether a patient is in need of IV fluid as here exemplified after surgery.

Original languageEnglish
JournalClinical Physiology and Functional Imaging
Volume37
Issue number3
Pages (from-to)314-316
Number of pages3
ISSN1475-0961
DOIs
Publication statusPublished - May 2017

ID: 161688891